3SM29

Qr code

Independent power supply with build-in power source,directly draws power from the incoming end to avoid the risk of protection function failure caused by external power supply failure.

● Overload protection
● Short circuit protection
● Isolation
● Controlling
● Used in residential building, non-residential building, industry, energy and infrastructure

-
+

Applications and functions

●   Incoming and outgoing function in distribution systems

●   Switching and protection of short circuit and overload for motors, transformers and capacitors

●   Stopping and switching off in an emergency in conjunction with lockable rotary operating mechanisms and terminal covers

●   Available in the following versions:

●   System protection: the overload and short-circuit releases are designed for the protection of cables, leads and non-motor loads

●   Motor protection: the overload and short-circuit releases are designed for optimized protection and direct-on-line starting of induction squirrel-cage motors

Features

●   Complete current range

●   High-breaking capacity

    (1) B: Basic breaking capacity type

    (2) N: Normal breaking capacity type

    (3) S: Standard breaking capacity type

 

    (4) H: High-breaking capacity type

    (5) G: Ultrahigh breaking capacity type

Frame rated current

Rated ultimate short circuit breaking capacity Icu 

20kA

35kA

50kA

65kA

85kA

A: 125 A

 N   
B: 160 ABNS L
C: 250 ABNSHL
D: 400 A NSHL
E: 630 A NSHL
F: 800 A NSH 
G: 1250 A  SHG
H: 1600 A  SHG

●   Microprocess controlled

3SM29 series circuit breaker (Inm ≥ 250) adopt advanced microprocess electronic release that can intelligentize the protection

●   Convenient installation

3SM29 series circuit breaker provides three installation types as follow:

Fixed installation with front connection and rear connection

Plug-in installation with front connection and rear connection

Drawer installation

Instruction of type code

Technical specifications

Selection and ordering data

Thermal Magnetic Type

Selection and ordering data

Thermal Magnetic Type

Electronic Type

Electronic Type

Electronic Type

Motor driven mechanism

Function

●   Used for opening and closing the circuit breaker remotely

Technical specifications

Model typeMD1MD2MD3
Application

3SM29-250,

3SM29-400

3SM29-125,

3SM29-160

3SM29-630, 3SM29-800

3SM29-1600

Operating voltage range(85 % - 110 %) Un
Rated control voltage

220 V AC, 380 V AC,

220 V DC, 110 V DC

220 V AC, 380 V AC,

220 V DC, 110 V DC

220 V AC, 380 V AC,

220 V DC, 110 V DC

Operating current (A)≤ 2≤ 0.5≤ 7.5
Start power consumption in 220/380 V AC (VA)510220660
Continuance power consumption in 220/380 V AC (VA)360110110 (180)
Start power consumption in 110/220 V DC (W)510220600
Continuance power consumption in 110/220 V DC (W)360110180
Opening time (s)0.10.10.1
Closing time (s)0.10.10.3
Eletrical life (times)400080003000
Protection degreeIP40

Selection and ordering data

Rotary handle operation mechanism

Function

●   Used for opening and closing the circuit breaker

●   Used for rotating the circuit breaker, not pushing-pulling it upwards-downwards

Selection and ordering data

Shunt release

Function

●   Used for opening the circuit breaker remotely

Technical specifications

Model typeSR91 SR92 SR93
Application

3SM29-125

3SM29-160

3SM29-250

3SM29-400

3SM29-630, 3SM29-800

3SM29-1600

Operating voltage range(70 % - 110 %) Un
Rated control voltage

220 V AC, 380 V AC,

220 V DC, 110 V DC

220 V AC, 380 V AC,

220 V DC, 110 V DC

220 V AC, 380 V AC,

220 V DC, 110 V DC

Response time (ms)≥ 20, ≤ 60
 Power consumption in 220/380 V AC (VA)150150150
Power consumption in 110/220 V DC (W)150150150

Selection and ordering data

Under-voltage release

Function

●   Used for opening the circuit breaker when energy cuts off or voltage goes below 70 % of the operating voltage

Technical specifications

Model typeUR91UR92UR93
Application3SM29-125, 3SM29-1603SM29-250, 3SM29-400

3SM29-630, 3SM29-800,

3SM29-1600

Action voltage range(35 % - 70 %) Ue
Guarantee close voltage range(85 % - 110 %) Ue
Guarantee no-close voltage range≤ 35 % Ue
Rated control voltage (V)

220 V AC, 380 V AC,

220 V DC, 110 V DC

220 V AC, 380 V AC,

220 V DC, 110 V DC

220 V AC, 380 V AC,

220 V DC, 110 V DC

Response time (ms)≥ 20, ≤ 60
Power consumption in 220/380 V AC (VA)101010
Power consumption in 110/220 V DC (W)444

Selection and ordering data

Auxiliary contact and alarm contact

Function

●   Indication of contacting status

●   Used for supplying electrical signal of the circuit breaker according to the operating position

Selection and ordering data

Accessaries introduction

Tripping curve

Microprocessor control panel

ST110-M (ST110-M/F) Microprocessor electronic release panel

ST110-H (ST110-H/F) Microprocessor electronic release's panel

Releasing curve

Microprocessor electronic release main function

Main function of microprocessor electronic release
Main circuit load indicationThe LED in panel indicates 60 %, 80 %, 90 %, 100 %
Power supply indicationThe LED in panel indicates
Self-diagnose indicationThe LED in panel indicates
Overload pre-warning indicationThe LED in panel indicates
Earth fault indicationThe LED in panel indicates
Thermal memoryRecord over-load cumulate caloric effect
Fast set protection character curveBasis on different purpose ,user can choose short-circuit release's character (curve F, R, B, M)

Signal output of the transition ray contact between breaker

and ST-200 Intelligentized control module

Overload pre-warning

releasing alarm

Earth fault alarm

Signal of breaker's ON / OFF

Releasing testTest socket

Setting panel parameter

User can reset the protection character

when the main circuit with or without power running

Switch commutating

Switch commutating

Switch commutating

Switch commutating

Switch commutating

Electronic release protection character curve

Protection performance of residual current release

Outline and installation dimensions

Installation type: Fixed, Plug-in, Withdrawable type

Breaker’s installation dimensions

Outline and installation dimensions

Outline and installation dimensions

Outline and installation dimensions

Outline and installation dimensions

Outline and installation dimensions

Outline and installation dimensions

Submit a consultation request

    We look forward to cooperating with you

    Please send us your support request.

      Image

      Title