Independent power supply with build-in power source,directly draws power from the incoming end to avoid the risk of protection function failure caused by external power supply failure.
● Overload protection
● Short circuit protection
● Isolation
● Controlling
● Used in residential building, non-residential building, industry, energy and infrastructure
● Overload protection
● Short circuit protection
● Isolation both for phase and neutral line
● Controlling
● Used for the protection of plants with switched neutral
● Used in residential building
Technical specifications
● Standard: IEC 60898-1
● Rated current In (A): 6, 10, 16, 20, 25, 32, 40
● Rated voltage Un (V AC): 230
● Rated frequency (Hz): 50/60
● Operational voltage Min / Max (V AC): 24 / 250
● Number of pole: 1P+N (1 modular width)
● Tripping characteristic: B, C
● Characteristic B (In): 3-5
● Characteristic C (In): 5-10
● Thermal operating limit : 1.13-1.45 In
● Rated switching capacity Icn (kA): 6
● Degree of protection: IP20, with connected conductors
● Electrical life(times): 4,000
● Mechanical life (times): 10,000
● Breaking capacity:
● Mounting position: Any
● Conductor cross-sections
● Solid and stranded (mm²): 0.75-16
● Finely stranded with end sleeve (mm²): 0.75-16
● Terminal tightening torque (N·m): 2.0
● Ambient temperature (°C): -25 ~ +45, max. 95 % humidity
● Storage temperature (°C): -40 ~ +75
● Altitude (meters): Max. 2,000
● Aonnection capacity (mm²): 1-16
References
● Additional components: page 189 ~ 191
Instruction of Type Code

Features
● The handle being sealable or equipped with padlock bracket avoids dangerous operation changes (ON/OFF)
● The handle provides a clear indication of the contact position
● Adequate printing of all data on the front provides long-term identification
● Energy limiting class: 3
● The emission of ionized gases is limited to the severest restrictions: 45 mm grid distance
● This MCB for household in accordance with: IEC 60898-1, B, C tripping characteristics
● Full sets of accessories
Selection and ordering data
IEC 60898-2 10 kA

Tripping Characteristic curves

Magnetic release
An electromagnet with plunger ensures?instantaneous tripping in case of short circuit. The?IEC 60898-1 distinguishes three different types,? following the current for instantaneous release: type?B, C
Thermal release
● The release is initiated by a bimetal strip in case of overload
● The standard defines the range of release for specific overload values
● Reference ambient temperature is 30 ºC
Outline and Installation Dimensions